Control Panels for Float Switches (CPF) are intrinsically safe and designed for use with Fluid Electronics' "float switch" sensors. The solid state circuitry is housed in a NEMA 4 water tight enclosure and provides from 1 to 4 channels for monitoring up to four independent sensing points. Bright LED's and a loud sounding horn warn of alarm conditions. Dry contacts are provided for controlling external devices such as pumps, valves or remote alarm stations. The CPF Control Panels can also be used as remote Audible and Visual Remote Alarms for any of Fluid Electronics' Control Panels.

SPECIFICATIONS
Control Relay Output Dry switch contact-SPDT per point, rated 3 AMPS at 120 VAC; selectable either normally open or normally closed
Response Time Typically 1/2 second
Indicators Alarm Conditions - Red Light On - Audible Horn On
Controls Reset Button silences horn; Test Button tests alarm circuits
Sensor Cable Standard 2 conductor # 18 AWG. Up to 5000' (provided by customer)
Terminal Blocks Pressure type, enclosed under metal barriers
Installation Distance Up to 5000' from Fluid Electronics Float Switch Sensors
Power to Sensor Low electrical energy; 12 VDC at 15mA, provided by Control Panel to each sensor. Safe for Class I, Div. 1, Groups A, B, C, D; Class II Div. 1, Groups E, G.
Power Input 120 VAC ( ± 10%, 60 Hz)
Fuse 0.1 AMP, 3 AG SLO-BLO
Operating Temperature -40°F to 160°F (-40°C to 71°C)
Enclosure Rating NEMA 4 - weatherproof
Weight 6 lbs. (2.7kg.) - 1 and 2 channel panels
11 lbs. (5 kg.) - 3 and 4 channel panels
Audible Alarm Loudness adjustable; auto silence-adjustable (optional)


SP 8 SWITCH PANEL

DESCRIPTION
Fluid Electronics, Inc. SP 8 electronic switch panel doubles the monitoring capability of a CPF Series alarm control panel. The switch panel allows two float switch sensors to use the same primary input alarm circuit. The SP 8 allows up to eight sensors to connect to four primary input alarm circuits. The switch panel allows the user to distinguish which sensor is in alarm by pressing the switch buttons for each individual input circuit. The SP 8 is most cost effective when used with a three or four channel alarm panel. It is also used when adding sensors to control panels that are already installed and do not have extra alarm input channels.

SPECIFICATIONS
Housing Construction Polycarbonate, 2 -half shells
Housing Color Industrial Gray
Housing Rating NEMA 4X, Weather and Corrosion proof
Installation Wall Mount, 4 x #8 screws
Dimensions 6-3/4" W x 4-3/4" H x 2-3/16" D
Overlay Construction 0.01" thick textured Lexan
Switch Buttons Pressure sensitive membrane, 8 domed buttons, moisture proof, normally open, ribbon cable connection to circuit board
Terminal Blocks 8 inputs, 4 outputs
Conduit Knockouts (1) 3/4", (4) 1/2"


For further information on Electronic Monitoring Equipment, navigate to any of the areas below.

Electronics Section Navigation:

Control Panels

Sensors

Alarms

 

 

About CSI
Contact CSI
Links
Search

    
[ Chemical | Water / Wastewater | Petroleum | Lubricants / Automotive | Service | Contact Us | Home ]

Copyright © 1999 Containment Solutions, Inc.